lg-1 hi flon

PFA Lined Megnatic Level Gauge

Slider-1 PFA Lined Megnatic(Watermark)
Slider-2 PFA Lined Megnatic(Watermark)

PFA Lined Megnatic
Level Gauge

As illustrated in the figure above shows diagram of level transmitting system which we provide a variety of CS-fabricated PFA-lined level gauge. By different process group of manufacture, we can provide and execute equipment designs suitable to the user’s application. Our process designers and product development engineers provide process data sheets to match the best-suited design with its GAD for applications. Physical fitness is ensured by our QC engineers determining acceptable working circumstances such as pressure rating, vacuum sustainability, and temperature suitability. Erection guidance is also provided to ensure the quality of the long-term outcome. In addition, lining vents as per pipe standards are provided in each segment to evaluate user fouling of the segments over long-term usage.
Benefits and Features of Hi-Flon Design
  1. One-Piece PFA-Lined Tank/Column with one-piece PFA-lined Elevated and Incline Nozzles from its structure, which helps in isolating the internal contact surface and protecting the metallic housing from corrosion.
  2. Dome-type structures can be lined with a one-piece PFA-Lined design that includes nozzles to reduce the possibility of leaking from the flange joints.
  3. Assured for Full Vacuum (-1 BAR) to Pressure (10 BAR).
  4. PFA lining Thickness : 6 MM±1 MM
  5. Easy-to-use PFA lining compares to glass-lining.
  6. Reliable construction of MS Fabricated PFA Lined Level Gauge against aggressive chemicals at high temperatures.
  7. Providing Vents to evaluate lining foul during its application.

Product development is subject to ANSI B 16.5 ASA#150 of IS2062 for flanges & ANSI 36.10 ASTM A-106 Grade B SCH-40/30 or IS2062 Shell Bend for Pipe with internal lining conformance to ASTM F1545.
PFA Lined Megnatic Level Gauge

150 NB to 1200 NB

5 MM–6 MM & in nozzles accordance to ASTM F1545

  1. Design temperature: 200 °C; working temperature: 180°C.
  2. Pressure: 6 BAR
  3. Vacuum: -1 BAR (Achieved by our mechanical interlocked lining technique)
  1. Spark Test: 15 KV to check for isolated metallic contacts after lining
  2. Hydrostatic Pressure Test: 7.5 Kg/Cm².
Contact-left-arrow hi flon

Let's Start
Something Great!

We are a full-service creative agency
Get in touch hi flon 4 hi flon

Location
E-503, Sumel-11, Nr Namaste Circle, Shahibaugh, Ahmedabad-380004, Gujarat.

PFA Lined Megnatic Level Gauge

All Rights Reserved | Design By